November 2007 Edition

Aluminum Wiring

Problems With Aluminum Wiring:           
From the 1940s through the mid-1970s, the United States experienced unprecedented suburban sprawl. As growing communities expanded, so did the need for electrical wiring components for electrical systems. However, in the mid-1960s through 1975, the shortage and expense of copper wire pushed contractors to find more cost-effective, alternative wiring methods.
E1
The copper crisis increased the demand for aluminum wire. With increased usage, new research soon arrived on the negative effects that aluminum electrical systems have at the connection points in branch circuits. Overheating in connections and wire splices was identified as the cause of home fires in several instances.           
In 1974, the U.S. Consumer Product and Safety Commission (CPSC) concluded that risks associated with aluminum wire systems presented "an unreasonable risk of injury or death." This lead to further investigation on fire and safety hazards associated with aluminum wire electrical systems. 
Research findings from The Report of the Commission of Inquiry on Aluminum Building Wire concluded that there are many different factors that possibly affect the contact resistance of aluminum wiring, including thermal expansion disparity and creep. At connection points, aluminum “expands and contracts three times the rate of copper,” which is explained by Jim Lardear in his article “The Problem of Aging Electrical Wiring.”
E2
In each circumstance that these temperature disparities occur, space is created that allows air to oxidize any exposed aluminum wire. When oxidation and corrosion build up from temperature differences, they cause increased resistance and overheating along the circuit. This is one of the major culprits that may lead to hazardous arcs and glowing connections, furthering the risk of home fires.           
The CPSC has found that 10 percent of home fires start in electrical distribution systems. In many of these situations, arc faults and problems due to expansion can be blamed. In fact, the CPSC has calculated that homes manufactured before 1972, using aluminum wiring systems, are 55 times more likely to have one or more connections that are hazardous versus homes wired with copper electrical systems. According to the United States Census Bureau’s American Housing Survey for the United States: 2003, an estimated 2 million homes during this time period were wired with aluminum electrical systems.
Solutions
E3
Installing secure, mechanical connections is an electrical contractor’s goal. With 50% of homes in the U.S. older than 50 years and over 2 million homes containing pre-1972 aluminum wiring, AlumiConn™ provides the safest pig-tailing solution for replacing wiring systems, offering the most reliable, cost-effective method for electrical contractors.
For more information go to King Innovations website: http://www.kinginnovation.com/
Source: http://www.alumiconn.com/wiring.html 

If you have a question, change of address, comment, home tip or would like to send Home Tips to your clients, send your letter to Home Tips, Christian Building Inspectors, Inc., 3697 Habersham Lane, Duluth, Georgia 30096. You can E-Mail your questions to us at rodharrison@christianbuildinginspectors.com. We reserve the right to edit questions for length.


Home Tips Available By Email
 
Due To The Increase In Distribution Cost, We Will Be Discontinuing The Delivery Of Home Tips To Your Office At The End Of This Year.
To Receive Them By Email, Just Drop Us A Note At: RodHarrison@ChristianBuildingInspectors.com.
 

Quote Of The Month

"Education is the best provision for old age.”

Aristotle


A Tip Of The Hat To:

Melissa Holcomb

Nest Brokers

6595G Roswell Road, Suite 800

Atlanta, Georgia 30328

**** Thank You****